Console
Door
Fig. 74
Set
Down
Up
Fig. 73
WARNING:
If you are not able to first set the travel limit for the open 
position, do not skip ahead and attempt to set the travel 
limit for the closed position. If the travel limits do not set 
and the door does not move in the intended direction as 
described in this section of the Operator’s Manual, do not 
use the garage door opener and contact customer service 
or a qualified service person for assistance. The use of a 
garage door opener that is not operating the garage door 
in the correct direction can kill or seriously injure someone 
in the moving door’s path.
To set the travel limit for the closed position:
Press and hold the DOWN button for three seconds. After 
you release the button, it will begin blinking and continue 
blinking until the travel limit has been set.
Press and hold the DOWN button to move the garage 
door to the closed position.
For fine adjustments, press and release the UP or DOWN 
buttons.
Once the door is in the closed position, press the SET 
button to program the travel limit. Once the travel limit 
is set, the DOWN button will stop blinking and shine 
continuously.
NOTE: If the safety sensors are obstructed during this 
process, travel limit information for the open and closed 
position will be erased. 
To test the travel limits:
NOTE: The garage door opener will not respond to the 
remotes or keypads until the travel limits have been tested. 
Press and release the UP button and ensure that the door 
moves to the programmed open position. The button will 
blink as the door moves then shine continuously once the 
door is in the open position.
Press and release the DOWN button to ensure that the 
door moves to the programmed down position. The button 
will blink as the door moves then shine continuously once 
the door is in the down position.
 NOTE: After testing is complete, the light for both the UP 
and DOWN buttons will turn off.
If the travel limits were set incorrectly, they can be cleared 
by pressing and holding the UP button for three seconds.  
If a buzzer sounds while you are setting or testing the travel 
limits, the garage door opener has detected a problem. 
Travel limit information for the open and closed position 
will be erased and cannot be reset until the problem is 
resolved. For details, refer to the Troubleshooting section 
later in the manual.
TESTING THE AUTOMATIC REVERSAL 
SYSTEM
See Figure 75.
DANGER:
Test the automatic reversal system after installation, prior 
to first use, every month and after any adjustments are 
made to the garage door travel limits. If the door contacts 
an object higher than 1-1/2 in. off the garage floor (approx. 
the size of a 2x4 laid flat), it should stop and reverse to 
the fully open position. If the automatic reversal system 
does not function properly, 
a closing garage door could 
kill or seriously injure someone in its path.