Use and Care Manual
41 - English
Press and release the UP/DOWN button on the indoor 
keypad to raise the garage door.
Place a 1-1/2 in. board (
approx. the size of a 2x4 laid flat) 
on the garage floor beneath the door
.
Press and release the UP/DOWN button on the indoor 
keypad to lower the garage door.
 When the door strikes 
the board, it should reverse direction immediately.
  NOTE: After the door contacts the board, a buzzer will 
sound five times and the garage door opener’s LED lights 
blink five times.
If the garage door reverses direction after contacting the 
board, the reversal system is working properly and no 
adjustments are needed. 
If the garage door stops before striking the board or 
strikes the board and then stops, increase the travel limit 
for the closed position and repeat the test.
If the automatic reversal system continues to fail, contact 
customer service or a qualified service person for 
assistance.
Fig. 75
2 x 4
Up/Down 
Button
INSTALLATION
WARNING:
DO NOT operate the garage door opener unless the 
automatic reversal system is working correctly. Following 
this rule will reduce the risk of death or serious personal 
injury. 
NOTICE:
This task requires the garage door opener to be 
connected to a power source. 
Install and wire the indoor keypad as described earlier in 
the Installation section.
Connect the garage door opener to an AC power supply. 
 NOTE: Make sure the power supply is normal household 
voltage, 120 volts, AC only, 60 Hz