PV Kit 2.0 Edge Manual

The right way to attach almost anything to metal roofs!
800.284.1412 www.lmcurbs.com
PV Kit 2.0 Installation Instructions
Installation Instructions
S-5!® Warning! Please use these products responsibly! Visit our website or contact your S-5! distributor for available load test results. The
user and/or the installer of these parts is responsible for all necessary engineering and design for the intended use of these parts in an
assembly or application. Note that a continuous ground must be followed in accordance with National Electric Code (NEC), ANSI/NFPA 70.
Installation in Canada must be in accordance with CSA C22.1, Safety Standard for Electrical Installations, Canadian Electrical Code, Part 1. For
UL 2703 Listed assemblies (listing pending) use with PV Modules having a maximum fuse rating of 25A or less. Prior to installation, contact
the local code Authority Having Jurisdiction (AHJ) to determine the proper grounding requirements. Visit www.S-5.com for more details.
Tools Needed
Screw Gun
3/16” Hex Bit Tip
(provided)
Calibrated Dial
Torque Wrench
1. Install the rst row of S-5! clamps, at the edge of the array:
It is critical that this row is straight. Install a clamp at both ends of
the row, by measuring from a reference point such as the eave of
the roof. Tighten the setscrews with Screw Gun and the included
Hex Bit Tip. The setscrews will dimple the seam material but will
not penetrate it. When relying on published load values, setscrew
tension should be verified periodically using a calibrated torque
wrench to ensure the tool is consistently achieving the proper
torque range (see Setscrew Torque Table below). Please see
installation instructions provided with clamps for specics.
Stretch a string line between the two end clamps to provide a
true line to mount the remaining edge clamps (Fig. 1).
To install PV Kit 2.0 On Standing Seam
Parts
2. Mount the PV Disks and the EdgeGrab/StandO Assembly
to the rst row of clamps: place the PV Disk atop the clamp and
thread the Male Portion of the StandO through the disk and
into the clamp. Drive the EdgeGrab/StandO Assembly down
with provided Hex Bit Tip (Fig. 2) until the base of the StandO
seats the disk in place and breaks the thread locking seal
between the StandO and Low Prole Bolt. Leave the grab up, to
allow space for a module frame. A 1/2” open end wrench can be
used to further tighten the StandO atop the disk if desired.
PV Disk
StandO
EdgeGrab/StandO Assembly
MidGrab/StandO Assem
bly
Wire Management
Tie O Holes
Module Placement
Bevel Guide
Bonding Teeth
Male Portion
cutaway for 1/2”
wrench option
EdgeGrab
Low Prole
Bolt
Accessory
Slot
3/16” Hex
Drive
3/16” Hex
Drive
Thread locking
compound
1.
2.
MidGrab
StandO
Low Prole
Bolt
S-5! Clamp Setscrew Torque Table (torque varies depending on roof material)

Summary of content (4 pages)