S-5-T and S-5-Z Install
S-5!® Warning! Please use this product responsibly!
Products are protected by multiple U.S. and foreign patents. Visit the website at www.S-5.com for complete information on patents and trademarks. For maximum holding strength, setscrews
should be tensioned and re-tensioned as the seam material compresses. Clamp setscrew tension should be veried using a calibrated torque wrench between 160 and 180 inch pounds when used
on 22ga steel, and between 130 and 150 inch pounds for all other metals and thinner gauges of steel. Consult the S-5! website at www.S-5.com for published data regarding holding strength.
Copyright 2012, Metal Roof Innovations, Ltd. S-5! products are patent protected.
S-5! aggressively protects its patents, trademarks and copyrights.
Installation Instructions
S-5!® Warning! Please use these products responsibly! Visit our website or
contact your S-5! distributor for available load test results. The user and/or
installer of these parts is responsible for all necessary engineering and design
to ensure the S-5-T or S-5-Z has been properly spaced and congured.
Notice to S-5! users: Due to the many variables involved with specic
panel products, climates, snow melt phenomena and job particulars, the
manufacturer cannot and does not express any opinions as to the suitability
of any S-5! assembly for any specic application and assumes no liability
with respect thereto. S-5! products are tested for ultimate holding strength
on various prole types and materials. This information is available from
the S-5! website: www.S-5.com. This document is an installation guide only
and the photographs and drawings herein are for the purpose of illustrating
installation tools and techniques, not system designs.
The S-5-T clamp is designed to t “T” shaped standing seam proles.
The S-5-Z clamp is designed to t “bulb” shaped standing seam proles.
Tools Needed
• Screwgun
• 3/16” Allen Bit Tip (Provided)
• Dial-Calibrated Torque Wrench*
(*For accurate tension values, do NOT use a clicking torque wrench.)
To Install S-5-T and S-5-Z:
1) Partially thread the setscrews into the clamp by hand.
2) Position clamp at desired location along seam with the bolt hole in the
correct (upslope or downslope) orientation.
3) Install by holding the small insert piece under the edge of the seam, then
roll the clamp into position over the seam and insert.
4) Tighten the setscrews at the base of the clamp using a screwgun and the
included screwgun bit tip. For optimal holding strength, setscrews should
be tensioned to 160 to 180 inch pounds on 22ga steel, and 130 to 150 inch
pounds on all other metals and thinner gauges of steel.
These instructions are for use by those experienced in the craft.
Always follow appropriate safety precautions and use appropriate tools.
3