Installation Manual

S-5-USF Mini / S-5-EF Mini Install
888-825-3432 | www.S-5.com
Installation Instructions
S-5!® Warning! Please use these products responsibly! Visit our website or
contact your S-5! distributor for available load test results. The user and/or
installer of these parts is responsible for all necessary engineering and design
to ensure the S-5-USF Mini or S-5-EF Mini has been properly spaced and
configured.
Notice to S-5! users: Due to the many variables involved with specific
panel products, climates, snow melt phenomena, and job particulars, the
manufacturer cannot and does not express any opinions as to the suitability
of any S-5! assembly for any specific application and assumes no liability
with respect thereto. S-5! products are tested for ultimate holding strength
on various profile types and materials. This information is available from
the S-5! website: www.S-5.com. This document is an installation guide only
and the photographs and drawings herein are for the purpose of illustrating
installation, tools and techniques, not system designs. Information
contained within is intended to apply to the document as a whole.
The clamps included in this installation guide are components of the S-5!
Utility System. The S-5-USF Mini is designed to
. The S-5-EF Mini is designed to t double-fold standing
seam profiles. When attaching to machine folded seams (regardless of panel
profile and geometry), S-5! clamps are designed to engage the seam as shown.
Tools Needed
Screw Gun*
3/16" Allen Bit Tip (Provided)
To Install S-5-USF Mini / S-5-EF Mini
1. Partially thread the setscrew into the clamp by hand.
2. Determine how to position the clamp. On many snap-together type seams,
the setscrew is opposite the open (or overlap) side of the seam. On some
seams, this aspect of clamp orientation is not critical.
3. Tighten the setscrew at the base of the clamp using a screw gun* and the
included screw gun bit tip.
The right way to attach almost anything to metal roofs!
S-5!® Warning! Please use this product responsibly!
Products are protected by multiple U.S. and foreign patents. Visit the website at www.S-5.com for complete information on patents and trademarks. For maximum holding strength,
inch pounds when used on 22ga steel, and between 130 and 150 inch pounds for all other metals and thinner gauges of steel. Consult the S-5! website at www.S-5.com for published data
Copyright 2014, Metal Roof Innovations, Ltd. S-5! products are patent protected.
S-5! aggressively p
rotects its patents, trademarks, and copyrights. Version 040914.
These instructions are for use by those experienced in the trade. Always follow appropriate safety precautions and use appropriate tools.
2
3
1
Above illustrations show S-5-USF Mini.
Inch Pounds Foot Pounds Nm
22ga steel 160–180 13–15 18–20
24ga steel and
all other metals
130–150 11–12.5 15–17
USF/EFI-V1.0-0915
S-5-USF Mini on snap lock profile.
S-5-USF Mini on double fold profile.
S-5-EF Mini on single fold profile.
Setscrews
dimple seam
material but
will not pierce.
When relying on published load values,
setscrew tension should be verified using calibrated torque wrench as
indicated below to ensure the tool is consistently achieving the proper
torque range. The slotted thru-hole in the flange is designed to
accommodate a variety of nut and bolt connections.
Once installed correctly, these clamps require no maintenance or
re-inspection for the life of the roof
* For time-saving tool recommendations, call S-5!
setscrews should be tensioned and re-tensioned as the seam material compresses. Clamp setscrew tension should be verified using a calibrated torque wrench between 160 and 180
regarding holding strength.