User's Manual

R&D / Automotive Electronics
Title Remote Keyless Entry System Specification Spec. No. DPE-AE-RK019912S
Written by
Rev. No.
A0
Date 24 . July. 2007 Page
10 / 23
If the above theft detection input is received at the arming mode, the type of theft is memorized at
the Rx EEPROM. But the alarm duration is not prolonged even if theft detection signal is
recognized during the alarm mode. That is, the Rx ignores the theft detection input until the
alarm is finished.
During the alarm is activated, if the “lock” , “unlock”, “trunk”, “panic” function code is received,
the Rx performs the function according to be received code and the burglar alarm (audible alarm
and visible alarm) is deactivated. If the “trunk” and “panic” function code is received, the Rx
does not perform the function and the burglar alarm is deactivated. And if the tamper switch
(passenger unlock disarming / driver unlock disarming / trunk unlock disarming) is ON, the Rx
stops the burglar alarm and goes to the disarming mode.
Theft
Detection
FLASH ING
BULB
HORN
500ms
250ms
250ms
28sec
5sec
[Figure 3. Timing Chart for Burglar Alarm]
3.3 DISARMING BY KEY CYLINDER
If the tamper switch (passenger unlock disarming / driver unlock disarming / trunk unlock
disarming) is ON, the Rx stops the burglar alarm and goes to the disarming mode.
3.4 SAFETY LOCK(AUTO DOOR LOCK AFTER 30SEC)
At the arming mode, if the door / trunk / hood open and the ignition on is not occurred during 30