3.2 BURGLAR ALARM
At the arming mode, if below signal input is recognized by the Rx, the burglar alarm (audible
alarm (horn) and visible alarm(hazard Lamp) ) is during 28 seconds operated and 5 seconds
paused. The alarm activating count is the option by customer.
① When the door open switch input is turned to low(GND) (at the moment of opening the door)
② When the hood open switch input is turned to low(OPEN) (at the moment of opening the
hood)
③ When the trunk open switch input is turned to low(GND) (at the moment of opening the
trunk)
④ When the ignition switch input is turned to high(BAT) (at the moment of IGN on)