Gas Countertop Griddle This manual contains important information regarding your purchased equipment. Please read the manual thoroughly prior to equipment set-up, operation and maintenance. Failure to comply with regular maintenance guidelines outlined in this manual may void the warranty. Please keep it for future reference after installation and do not throw it away! This is a universal installation and operation instruction book which would apply to different models.
WARNINGS • Do not store or use gasoline or other flammable vapors or liquids in the vicinity of this or any other equipment. • Improper installation, adjustment, alteration, service or maintenance can cause property damage, injury or death. • Read the installation and maintenance instructions thoroughly before installing or servicing this equipment. • Have the equipment installed by a qualified installer in accordance with all federal, state and local codes. • Do not install or use without all 4 legs.
• The area in front and around the equipment must be kept clear to avoid any obstruction of the flow of combustion and ventilation air. • Adequate clearance must be maintained at all times in front of and at the sides of the equipment for servicing and proper ventilation. Pressure Regulator: • All commercial cooking equipment must have a pressure regulator on the incoming service line for safe and efficient operation. The regulator provided for this equipment is adaptable for both Natural gas and LP gas.
LIGHTING THE PILOT: The manifold units are equipped with standing pilots and each should be lit immediately after the gas is supplied to the equipment. 1. Before attempting to light the pilots, turn off the main gas valve to the equipment and wait 5 minutes to clear the gas. 2. Turn off all gas control knobs. 3. Turn on control valve and light all pilots. 4. The pilot burner must be lit from the top. Hold an ignition source and light the pilot. When the flame is stable, remove ignition source. 5.
OPERATION: Before initial use, turn the gas control knob to the maximum setting and allow the equipment to burn-in for 20 minutes. Seeing smoke coming from the cooking surface is normal during burn-in. After 20 minutes of burn-in, equipment is ready for use. 1. To ignite the burners, depress and turn the gas control knob to high position. 2. After cooking is done, please turn the valve to off position. For thermostatic controlled griddle, the operation procedure is same.
griddle to a low temperature (300-350°F) and apply a small amount of cooking oil – about one ounce per square foot of surface. Use a soft lint-free cloth to spread the oil over the entire griddle surface to create a thin film. Wipe off any excess oil with a cloth. Repeat the procedure until the griddle has a slick, mirror -like finish. This will also help reduce the sticking of cooked food product. USING THE GRIDDLE To preheat, turn the burners on about 20-25 minutes before cooking.
PROBLEM Burner does not come on when the control knob is turned on POSSIBLE CAUSES 1. Problem with gas valve. (Call for service) 2. Pilot burner not lit. (Call for service) 3. Low gas pressure. (Call for service) Pilot burner will not light 1. Manual gas valve not turned on. 2. Obstructed pilot orifice. (Call for service) 3. Pilot gas turned off at pilot. Adjust pilot to allow gas flow.4. Low gas pressure. (Call for service) Pilot burner will not stay lit 1. Obstructed or wrong size pilot orifice.
Product Specification Sheet MODEL MG-16 MG-24 MG-36 MG-48 STYLE(Manual) Single Burner 2 Burners w/ individual control 3 Burners w/ individual control 4 Burners w/ individual control MANIFOLD Total B.T.U. PRESSURE per Hour Natural Gas 4.0" W.C. 30,000 Natural Gas 4.0" W.C. 60,000 Natural Gas 4.0" W.C. 90,000 Natural Gas 4.0" W.C. 120,000 Natural Gas 4.0" W.C. 150,000 MANIFOLD Total B.T.U. PRESSURE per Hour Natural Gas 4.0" W.C. 30,000 Natural Gas 4.0" W.C.
Code Description MG-16 1 Griddle plate 2 MG-36 MG-48 MG-60 20129087001 20129088001 20129089001 20129090001 20129091001 knob 301110274 301110274 301110274 301110274 3 oil pan 20129087008 20129087008 20129087008 20129087008 20129087008 4 pilot 302130019 302130019 302130019 302130019 302130019 5 gas valve 302220059 302220059 302220059 302220059 302220059 6 foot 302090047 302090047 302090047 302090047 302090047 7 burner assy 302130363 302130363 302130363 3021303
3 oil pan 20129087008 20129087008 20129087008 20129087008 20129087008 4 pilot 302130019 302130019 302130019 302130019 302130019 5 gas valve 302220045 302220045 302220045 302220045 302220045 6 foot 302090047 302090047 302090047 302090047 302090047 7 burner assy 302130363 302130363 302130363 302130363 302130363 302201568 302201569 302201570 302201571 302201572 8 inlet gas pipe 9 Pilot gas pipe