SDS

1of 2
Client:
Procedure
Results
24.5 44
Can 1 Can 2 Can 2 Can 4 Can 5 Can 6 Can 7 Can 8 Can 9
Test Can 1 Can 2 Can 2 Can 4 Can 5 Can 6 Can 7 Can 8 Can 9
Ignition (Y/N) No No No No No No No No No
Ignition (Y/N)
Ignition (Y/N)
Ignition (Y/N)
Ignition (Y/N)
Ignition (Y/N)
Cert # 4305.01
Temperature (˚C)
Relative Humidity (%)
Initial level of filling
Test Position?
upright
upright
upright
100%
100%
100%
100 Collip Circle, Suite 220, London, ON N6G 4X8 - www.delltech.com - Tel: 519.858.5021 Fax: 519.858.5026 Ver. 30-10-2015
Shaken before discharge?
Yes
Yes
Yes
Straw/ No Straw?
No Straw
No Straw
No Straw
This report shall not be reproduced except in full, without the written approval of the laboratory. The results relate only to the items tested.
The aerosol is sprayed in the direction of the ignition source at intervals of 15 cm to observe if ignition and sustained
combustion takes place. Ignition and sustained combustion is defined as when a stable flame is maintained for 5 seconds.
UN TDG Manual of Tests & Criteria Part 3, Section 31.4 - 2008/47/EC 6.3.2 - Ignition Distance Test for
Spray Aerosols
Testing commences at the 15 cm distance and is incrementally increased by 15 cm if ignition is observed or decreased by 15
cm if ignition is not observed.
Distances not tested are left blank.
Test performed in upright position
Net
Volume
13.10
Sabre Red - pepper spray #IT-SPKCR-14-RM
18-0136
May 25, 2018
21631A-25-05-2018
Security Equipment Corp
747 Sun Park Dr
Fenton, MO, USA
63026

Summary of content (2 pages)