Service manual
SYNTIA CAPPUCCINO 02 TECHNICAL SPECIFICATIONS
Saeco International Group Page / 03
STAND-BY Description and values
Input time (min - max) 15 minutes - 180 minutes
Input time (default) 60 minutes
Input time set by user Yes
Input time set by
the Production/Service Dept
Yes
Boiler temperature during Stand-by Boiler OFF
03
DREG DRAWER Description and values
Time-out for dreg drawer 5 sec.
Alarm to empty dreg drawer block after
(double expresso as the last dispensed product)
8 lots of dregs
(9 lots of dregs)
Warning to empty dreg drawer No
Reset dreg counter Each time the dreg drawer is removed for at
least 5 seconds, even if the "empty dreg drawer"
alarm is not triggered
WATER TANK Description
Level sensor Yes
Water reserve (pulses) 200
Water reserve modiable by
the Production/Service Dept
No
"Fill tank" alarm Yes
"No tray" alarm No
Water mains No