Service manual
SYNTIA CAPPUCCINO 04 OPERATING LOGIC
Saeco International Group Page / 08
Descalingindicationwithanti-scalelter
(only in appliances equipped with a display)
The water hardness is set on the basis of the
regional water hardness analysis (1, 2, 3, 4).
Disabledlter:
If the function is disabled, the electronic system
counts the ow meter pulses, recording one pulse
for every revolution.
Enabledlter:
If the function is enabled, the electronic system
counts the ow meter pulses, recording one pulse
for every two revolutions.
"Changeanti-scalelter"indication
The electronic system uses the ow meter pulses
to keep track of the amount of water that ows
and once the dened litres are exceeded (based
on the water hardness setting), the "Replace lter"
indication is triggered.
Anti-scalelter
Function:
Reduced limescale deposits that take longer to form.•
Improved water quality.•
Better taste due to ideal water hardness.•
Descalingduration/efciency:
- 10° dH•
60 litres•
2 months•
To obtain a linear characteristic of its effectiveness,
throughout the duration of the descaling process, the
water is split according to the degree of hardness in a
three-phase by-pass (A,B and C).
See small picture.
Bypass
4.14 Anti-scalelter
4.12. Descaling request
360°
1 rev
Number of pulses
Enabled
lter
Disabled
lter
Flow meter pulses
08