5.2. Error messages
code brief description description
01 blocked coffee grinder
the coffee grinder is blocked (jammed grinder
blades or sensor is not reading properly)
03 brewing unit blocked in ‘work’ descent time-out exceeded
04 brewing unit blocked in ‘home’ ascent time-out exceeded
05 blocked water circuit water does not ow in the ow meter
06 frother unit solenoid valve short-circuit in a solenoid valve of the frother unit
10 coffee boiler short-circuit coffee boiler temperature sensor short-circuit
11 coffee boiler in open circuit coffee boiler temperature sensor in open circuit
12 steam boiler short-circuit steam boiler temperature sensor short-circuit
13 steam boiler in open circuit steam boiler temperature sensor in open circuit
14
various temperature errors
(in the coffee boiler)
coffee boiler temperatures out of control
15
various temperature errors
(in the steam boiler)
steam boiler temperatures out of control
16 coffee unit short-circuit brewing unit microswitch short-circuit
17 not used
18 clock error memory fault or impossible to set
19 no zero crossing
no zero crossing on board, could also be caused by
the power board
20 not used
06