Service manual

SYNTIA CAPPUCCINO 07 DISASSEMBLY
Saeco International Group Page / 09
7.7. Boiler
1
7.8. Stopcock
1
06
2
1) Loosen the screws shown.
4) Loosen the screw and remove the plastic support.
Disconnect the pipes and the connections.
1) Remove the boiler pin by loosening the
screws shown.
2/3) Loosen the screws shown.
4) Loosen the screws shown and remove
the structure base insert.
5) Loosen the screws shown and remove
the water connections and the stopcock.
2
3
5
4