Service manual

Level M5 : System Settings
System parameter values are shown at this level:
5.1 SW Version
5.2 Boot Version
5.3 Aroma Setup (imp.) Number of pulses set for medium aroma.
5.4 Temp. Standby From 50° to 80°C.
5.5 Cup. temp.
5.6 Standby temp. Standby time can be varied in 15 minute intervals.
5.7 Flowrate (L/h) Water flowrate.
5.8 Language
5.9 Water Hardness
5.10 Lcd Backlight Display brightness.
5.11 Lcd contrast Display contrast.
5.12 Grounds Limit Stop coffee grounds.
5.13 Grounds Left Coffee grounds counter.
5.14 Grounds Warning Empty coffee grounds.
5.15 W.Filter C. Date Date Aqua Prima filter was installed.
5.16 Service Date (to be added after servicing).
5.17 Production Date
Level M4 : Products Settings
The parameters for each different beverage are shown at this level; these parameters can be modified by opening each item
using the coffee key and selecting with the touch-ring.
4.1 Espresso Settings:
4.1.1 Product Qty. (imp.) Number of water pulses.
4.1.2 Aroma Displays coffee grinder pulses in 60-150 pulse range.
0: pre-ground (0 pulses); 1: mild (- 10% medium); 2: medium; 3: strong (+10% medium).
4.1.3 Prebrewing Prebrewing 1: enabled; 0: disabled; 2: long.
4.1.4 Temperature Shows temperature in °C. Low (-3°C average), average, high (+3°C average).
4.2 Coffee Settings:
4.2.1 Product Qty. (imp.) Number of water pulses.
4.2.2 Aroma 0: pre-ground; 1: mild; 2: medium; 3: strong.
4.2.3 Prebrewing 1: enabled; 0: disabled; 2: long.
4.2.4 Temperature in °C
4.3 Long Coffee Settings:
4.3.1 Product Qty. (imp.) Number of water pulses.
4.3.2 Aroma 0: pre-ground; 1: mild; 2: medium; 3: strong.
4.3.3 Prebrewing 1: enabled; 0: disabled; 2: long.
4.3.4 Temperature in °C
15/17
TALEA Section 05