Technical and Dimensional Data Saf-T Vent SC ® 3"/5" & 4"/7" Concentric Reduced Clearance Double Wall for Special Gas Vent and/or Sealed Combustion Systems Also For Venting Listed Gas or Oil Fired Appliances Listed as Suitable For Venting With Type L Systems Tested and Listed to UL 1738/ULC S636 UL641 & ULC/ORD-CC441 by Underwriters Laboratories, Inc 5030 Corporate Exchange Blvd Grand Rapids, MI 49512 Call (800) 772-0739 Fax (800) 972-1421 Canada Sales: 888-735-5475 www.heatfab.
Saf-T Vent® SC DOUBLE WALL SPECIAL GAS VENT TABLE OF CONTENTS CATEGORY PART DESCRIPTION Introduction PAGE 3 Accessories Vertical / Horizontal In-Line Drain Section Condensate Drain Tube Kit 4 4 Adapters Single Wall Adapter / Appliance Adapter Air Intake Tee 5 5 Elbows 45° Elbow 90° Elbow 6 6 Straight Lengths 6" Length 1’ Length 2’ Length 3’ Length Adjustable Length 7 7 7 7 7 Supports & Hanger Vertical Support Leg 0” Clearance Support Clamp 1" Clearance Support Clamp Outer Jacket Support Cl
Saf-T Vent® SC DOUBLE WALL SPECIAL GAS VENT Introduction: Saf-T Vent SC is an advanced concentric vent system designed for zero clearance installation in residential and light commercial applications. The inner wall is constructed from superferritic AL 29-4C®. The outer wall is stainless steel, providing durability and a lasting finish.
Saf-T Vent® SC DOUBLE WALL SPECIAL GAS VENT Accessories: Vertical/Horizontal In-Line Drain Section — Use to drain away condensate from the vent system. The unique design of this part allows it to be installed in a horizontal, vertical or inclined orientation. Continuous horizontal runs in excess of 30 feet require a condensate drain. Drains may also be required by the manufacturer. High temperature silicone rubber tubing is available separately, see below.
Saf-T Vent® SC DOUBLE WALL SPECIAL GAS VENT Adapters: Single Wall Adapter/Appliance Adapter — Use to transition from single-wall to Saf-T Vent SC. The male end connects to Saf-T Vent EZ Seal or Saf-T Vent appliance adapters and flue collars. The outer diameter collar is vented and must not be blocked during installation or operation.
Saf-T Vent® SC DOUBLE WALL SPECIAL GAS VENT Elbows: 45° Elbow — Use to achieve offsets or changes in the direction of the vent system. The degree of these welded seam elbows is not adjustable. Part Number DIM - A Nominal Vent Pipe Diameter SC03E45 SC04E45 3 4 DIM - B Nominal Outer Jacket Diameter DIM - C Rise DIM - D Run 5 7 3.1 3.3 3.7 4.3 DIM - E Combined Installed Height 11.60 13.03 DIM F Offset 4.8 5.
Saf-T Vent® SC DOUBLE WALL SPECIAL GAS VENT Straight Lengths: Install vent with a continuous pitch of 1/4" per foot, sloping upward toward the termination (unless otherwise specified by the appliance manufacturer). It is important to provide adequate support to a Saf-T Vent SC system. Refer to installation instructions for support specifications.
Saf-T Vent® SC DOUBLE WALL SPECIAL GAS VENT Supports: Vertical Support Leg — For use on vertical systems to provide support. The 20-gauge stainless steel support legs can be used below or above the roof, and can be used in pairs for extra stabilization. Hardware to attach the support to the structure is not provided; attach using best construction methods. Be sure to consider clearances when planning the system. Never drill or screw through the Saf-T Vent SC inner vent conduit.
Saf-T Vent® SC DOUBLE WALL SPECIAL GAS VENT Termination Accessories: Fire Stop / Support / Wall Plate— A fire stop may be required anytime Saf-T Vent SC penetrates combustible floors, walls, or ceilings. Remove any insulating material from the floor, wall, or ceiling cavity for at least 1 inch around the vent. Review fire codes and consult with local building code officials to determine the necessity for a firestop. This part provides added support when used at the bottom of a vertical chase.
Saf-T Vent® SC DOUBLE WALL SPECIAL GAS VENT Terminations: Horizontal Termination Adapter— Use to complete the Saf-T Vent SC system after penetrating an exterior wall. Standard Saf-T Vent terminations connect directly to the adapter. The screened openings release excess heat from the system and must not be blocked. On Sealed Combustion systems the screened openings supply combustion air to the appliance.
Saf-T Vent® SC DOUBLE WALL SPECIAL GAS VENT Terminations: Tee Termination with Screen — Use as a termination on horizontal or vertical systems, as specified or allowed by the appliance manufacturer. Part Number 9390TEE 9490TEE C DIM - A Nominal Diameter DIM - B Installed Length DIM - C Tee Body Width 3 4 5.5 6.
Saf-T Vent® SC DOUBLE WALL SPECIAL GAS VENT Terminations: Screen Termination — Use as a termination on horizontal or vertical systems, as specified or allowed by the appliance manufacturer. Part Number DIM - A Nominal Diameter 9392 9492 3 4 A 1.25 INSTALLED LENGTH SCREEN Screen Termination Rain Cap — Use as a termination on vertical systems. Category I and II appliances require a raincap or other device to prevent rainwater from entering the vent.