User's Manual

INTEGRA User Manual INSTALLATION
14
Assembly procedure
Tools required: 13mm (0.512”) wrench (comes in package)
1
Using 13mm wrench slightly loosen three hex
flange bolts [1] and hex flange bolt, nut and eye
screw [3] interconnecting clamps for housing
and pipe [7].
2
Attach vertical alignment eye screw [4] to clamps for
housing and pipe [7] using hex flange bolt [2] and
screw on two hex flange nuts [8]. Make sure that both
eye screws are positioned as shown in the image
(turned to the back side of clamps) and the gap
between each two flange nuts on eye screws should
be 15..20mm (0.6..0.8 in.). Do not tighten both hex
flange bolts [3] and [2].
3
Screw on one hex flange nut [9] on each of
threaded rods [8]. Note that flange nuts should
be screwed on exposing approx. 15mm (0.6
in.) of threaded rods.
4
Screw on each threaded bolt into four available
threaded holes of mounting clamp. Note that threaded
bolt should be visible from other side of the clamp not
more than 2mm. Tighten hex flange nuts [9] with
torsion 20..25 N·m.
SAF Tehnika JSC