INTEGRA User Manual WEB GUI
47
firmware switch
Use to check running firmware bank and bank that will be
used at the next boot.
firmware switch
<fs|fw1|fw2|toggle>
Use to define bank that will be used at the next boot.
“fw1” and “fw2” subcommands set appropriate bank,
“toggle” forces to set other bank than the running one, “fs”
is factory defined emergency bank, which is used if both
“fw1” and “fw2” fail.
Configuration à IP configuration
IP address configuration page is available in “System” menu (SystemàConfigurationàIP
configuration).
1) IP address - allows specifying IP address of Integra you are currently logged in.
Default IP address is 192.168.205.10 or 192.168.205.11 – depending on which side
the specific Integra is – low side has 192.168.205.10 IP address and high side –
192.168.205.11;
Integra IP addresses need to be in the same subnet..
2) IP Mask – allows specifying IP mask of Integra you are currently logged in. Default
IP mask is 255.255.255.0;
3) IP gateway – allows specifying gateway of Integra you are currently logged in. By
default gateway is not specified;
4) Ethernet MAC address – shows the MAC address of Integra you are currently
connected to;
5) Remote IP address – shows IP address of remote (far-end) Integra. By default
remote IP address is being retrieved automatically and therefore “Auto” checkbox is
selected. Unselect it to enter remote IP address manually;
6) By pressing „Execute configuration” changes made to the corresponding section
apply only for the local side Integra.
SAF Tehnika JSC