Figure 1.11 PhoeniX G2 1+1 SD configuration
PhoeniX G2 1+1 Full protection configuration:
1+1 HSB, FD and SD full protection is provided. SD supports only fixed hot-
swap role primary or secondary
This protection type protects the link also against IDU, power supply and
interface failures
In case of protection, when the Primary link fails, the secondary re-configures
itself to the Primary role
Figure 1.12 PhoeniX G2 1+1 full protection configuration
2.5 Gbps SFP modules must be used for both IDU FO interconnection. In Design Type 511
both SFP ports work in Forced 2G5” mode.
PhoeniX G2 2+0/2+0 XPIC configurations:
2+0 configuration is used to aggregate payload traffic (capacity doubling). In
this case 2 frequency channels are required
2+0 XPIC configuration is used to aggregate payload traffic using 1 frequency
channel in both polarizations Vertical and Horizontal simultaneously