Users Manual Part 1

Phoenix G2 IDU User Manual INSTALLATION
SAF Tehnika JSC
40
Chapter 2: INSTALLATION
Getting started
The installation of Phoenix G2 IDU and ODU link involves the following steps:
- Install the Phoenix G2 IDU in 19 rack: as the IDU is ½ width of the 19” inch rack position,
there are two options how to install it in the rack:
Option one: Single device installation: attach blank panel and bracket to the IDU (all
included in the package). Install the IDU in the rack using attached blank panel and rack
mount bracket.
Figure 2.1 Single device installation
Option two: Dual device installation: interconnect two devices (IDU and EMM, or IDU with
IDU) using dual device mount kit, attach brackets to each device. Brackets are included in
the package of IDUs; dual device mount kit is included in EMM module package, and can
be ordered as an optional accessory if two IDUs must be interconnected.
Dual device mounting kit includes aluminium mounting profile (P/N EASMEX03) which
must be inserted in side panel grooves of IDUs thus fastening both devices together. In
order to fix it and avoiding of both IDU movements use mounting plate (P/N
WAKMEXS1.001) for fixation. The mounting plate must be attached to IDUs on back-panel
using already existing screws from the IDUs. Those screws must be removed and used for
attaching the mounting plate to IDUs.
1
Insert the aluminium mounting profile in side
panel grooves of IDUs, fix it using setscrew with
square nut
2
Remove 2 existing screws from both IDUs back panel