Users Manual Part 1

Phoenix G2 IDU User Manual WEB GUI
SAF Tehnika JSC
65
Status Counters Modem
This section displays basic modem performance counters and built-in Bit Error Rate (BER)
counters. For BER counter only unassigned capacity will be used (Refer to Config Ports
MUX section)
Figure 3.18 Status
Counters
Modem” page
1) FEC RX Blocks the overall number of received airframes
2) FEC Corrected Blocks the number of air-frames which were repaired by FEC (Forward
Error Correction). This number represents a fragment of the FEC RX Blocks
3) FEC Uncorrected Errors the number of air-frames which could not be repaired by FEC.
This number represents a fragment of the FEC RX Blocks
4) Uncorrected Last Second the number of air-frames which could not be repaired
during the last second
5) FEC Global Rate the ratio of FEC Uncorrected Errors / FEC RX Blocks
6) FEC Actual Rate same as above but for latest second only
7) Uncorrected TLE time since last error; a number of seconds from the last error
occurrence. It should correspond to the time since pressing the button
8) Uncorrected TBE time between last two error events
9) Uncorrected EFS error free seconds; it should correspond to time since pressing the
button
10) Uncorrected ERS error seconds; number of seconds during which errors occurred
11) Status BER tester synchronization status (sync|nosync) or n/a when there is no
active link to the remote side or free capacity left for the BER tester