HB-G100 Series User Manual for Intelligent Burglar Alarm Host Ningbo Saferhome Electronics Co., Ltd. We are honoured that you have chosen our security products. Thanks for your wise selection. To make full use of its performance and ensure stable operation of the host, please carefully read this User Manual before operating the host. For any questions, please don don’’t hesitate to consult our Customer Service Department or agents.
Table of Contents I. Definition............................................................................2 II. Operating Precautions..........................................................4 III. Main Characteristics and Functions...................................4 IV. Name and Usage of Main Components..............................6 V. System Installation.............................................................11 VI. Operating Instructions......................................................
Introduction HB-G100 Series Intelligent Burglar Alarm Host is an intelligent long-range wireless transmission alarm system. This system adopts advanced microprocessor as control core and has voice prompts, easy to install and operate. It can learn codes of 5 remote controllers and 120 HB-T001 Series solar-powered wireless active infrared detectors, all of which constitute a complete long-range wireless alarm service system.
zone) in which the host can receive shielded signals, and can not receive any alarm signal temporarily. Full Arm It refers to the state in which all alarm detectors in full arming zone or part arming zone enter into alert state. Partial Arm It refers to the state in which all alarm detectors in part arming zone enter into alert state. User Password It refers to the password through which user can arm/disarm zones. Set-up Password It refers to the password used for user set-up.
II. Operating Precautions � Please carefully read this User Manual and pay more attention to labels and directions on the alarm host before operation. Check whether all wire connections are correct and then turn the host on so as to avoid any damage to the host. � The alarm host has no explosion-proof function, which cannot be directly installed in Class I, II or III hazardous locations (i.e.
security threats and 2 groups of telephone numbers of the alarm receiving centre. The telephone numbers of the alarm receiving centre must be fixed telephone numbers, which can be dialled preferably when an alarm is triggered under telephone alarm mode. � � Alarm or failure information can be displayed on the digital display. The dialling times can be set. � External 12V backup battery input.
IV. Name and Usage of Main Components Keyboard Panel 1、Keyboard 1) “RUN” Indicator: “RUN” Indicator blinks when the keyboard is connected to the host, which means the keyboard is well connected with the host. 2) “SET”Indicator: When “SET”Indicator lights up, that means the host is getting into set-up mode. A correct password is required for entering into set-up mode. In this mode, users can modify alarm mode and alarm time, and set alarm informed telephone numbers etc.
host gets ready for receiving alarm signals from partially armed zones within the system and giving out alarm. 6) “RECORD” Indicator: In set-up mode, users can prerecord a voice message to play back at the time when a call is answered to respond to an alarm. When a voice message is recorded, “RECORD” Indicator will light up.
minute. 15) “Emergency Zone” Indicator: “Emergency Zone” Indicator will light up only when set-up is performed for an emergency zone. Once emergency zone set-up is completed, the indicator is not turned on even when an alarm occurs. 16) “Doorbell Zone” Indicator: “Doorbell Zone” Indicator will light up when set-up is performed for a doorbell zone. Once doorbell zone set-up is completed, the indicator is not turned on even when an alarm occurs.
Installation & Wiring Diagram of Engineering Host 9
① Mains Supply Input: The alarm host adopts AC 220V±10% 50Hz input, and the input terminal is connected in series with a 0.5A fusion tube. ② External Backup Battery Input: The host adopts DC12V7Ah external backup battery input. ③ External Siren Output: A DC 12V siren (current: <0.6A) can be connected to the alarm host. ④ Local Call Phone Line Socket: It is used to connect with local call phone line (also called outside line).
Connection Principle: The normally open detector shall be connected in parallel with a 2.7KΩ resistor, while the normally closed detector shall be connected in series with a 2.7KΩ resistor. Detector1 Detector2 Detector 3 Detector1 Detector2 Detector 3 B B C C 2.7k 2.7k Connection of several normally open detectors Connection of several normally closed detectors Mixed connection of normally open detectors and normally closed detectors V. System Installation 1.
from damaged by mouse or other rodents. ④ The type and specification of detectors and cables in each defense zone should be labeled on construction drawings (The usage of each wire within a cable shall be marked). ⑤ All construction drawings should be archived for facilitating maintenance of the host system. 2.
intended for the host, and defense zones 000-007 are mixed wired/wireless defense zones in which it is not recommended to install wireless detectors. (I) Add/Delete Remote Controllers The host can learn codes with 5 remote controllers, which are numbered 10, 11,12,13,14 respectively. To add/delete remote controllers, please follow the following procedures: 1.
panel of the host. “Disarm” Key: Press “Disarm” key to disarm the host (except for shielded zone, doorbell zone and emergency zone). The function of “Disarm” key is the same as that of F3 shortcut key on the keyboard panel of the host. Emergency Key: Press Emergency Key to activate emergency alarm whether the host is in Arm mode or Disarm mode. The function of Emergency Key is the same as that of F4 shortcut key on the keyboard panel of the host.
The first four steps of deleting a remote controller are the same as those of adding a remote controller. Step 5: Enter 19 and # after 19, and then the host gives out a voice prompt “Delete all remote controllers”. Step 6: Press “#” key again, and then the host gives out a voice prompt “Ding”, which means a remote controller is successfully deleted. (I) Add/Delete Detectors The host can learn codes with 120 detectors.
【Note】 a. Detectors (numbered 000-119) shall be added in accordance with the same procedure. b. To let the host learn codes of detectors continuously, enter 011 and # 11 after the host completes learning the first detector, and then activate the next detector to let the host learn the code of the next detector until the host completes learning codes of all detectors. 2.
those of adding a detector, so please refer to the first four steps of the procedure for adding a detector. Step 5: Enter “010” and “*”, and then the host will give out a voice prompt “Now, the host is serving a fully armed zone. Please enter the attribute of the defense zone”(The attribute of all defense zones is set to“Fully Armed Zone”as default.
Reasons for Failing to Learn Codes Coding Redundancy: If the wireless code currently required to be learned by the alarm host has exited in the alarm host, that is, this code has been learned by the alarm host, it can not be learned again by the alarm host. If the alarm host requires learning this code, the existing code in the alarm host shall be deleted.
6) Dialling Times: 5 7) Siren Duration: 30 minutes 8) Leaving Time: 5 seconds 9) Entry Time: 0 second 10) Ringing Times Set via Remote Control: 9 times 11) Defense Zone Attribute: Full Arm 3. Detailed Programming Operation of Alarm Host All programming operations below shall be performed in set-up mode.
② Command Function: On-site Alarm Mode Command Grammar: 3# Function Description: This command enables the host to work under on-site alarm mode in which the host can not dial any telephone and check outside line, as well as to cancel all alarm information. Operating Steps: “###”(Please enter the preset password)+ “112233#”(The host enters into adjusting mode ) +“3#” ( The host is fully armed, and on-site alarm mode is activated).
again)+“BBBBBB#”. If you have forgotten the preset password indiscreetly, you shall contact our customer service centre or your local distributor for help. 5) Command Function: Modify User Password Command Grammar: 9 # A A A A A A # B B B B B B # B B B B B B #. “A A A A A A” is an old 6-digit user password, and “B B B B B B” is a new 6-digit user password. Once user password is modified, the old user password will be automatically invalid. To enter into set-up mode again, users must enter the new password.
Step 3: Enter “10” (10 represents informed phone number) and “#”, and then the host will give out a voice prompt “Please enter an informed phone number”. Step 4: Enter a preset phone number and “#” to finish the set-up. (If the input phone number is wrong, delete it and then enter a correct phone number. For more details, please refer to “How to delete informed phone numbers”. ). 【Note】a.
For the first two steps, please refer to the above mentioned procedure in SET mode. Step 3: Enter 19 and #, and then the host will warn users through voice message to delete all informed phone numbers”. Step 4: Press “#” key again, and then the host will indicate a remote controller has been successfully deleted. ② Command Function: Set Ringing Times by Remote Control Function Description: “D D” is ringing times (05-15) set to determine when the alarm host will enter into long distance set-up mode.
Press 2 5 # to select the medium on-site alarm volume; Press 2 6 # to select the large on-site alarm volume Press 2 7 # to select the maximum on-site alarm volume Operating Steps: “###”(Please enter the preset password)+“112233#”(The host enters into adjusting mode)+“27#”(for trial listening of alarm volume of the host). Note: Once this set-up is finished, the preset alarm volume will be automatically modified.
② Command Function: Audition the Record Command Grammar: 3 1 # Function Description: Press 3 1 #, and then 2-3 seconds of record will be played from the built-in speaker of the host. 7. Select Playing Content ① Command Function: Select playing the record Command Grammar: 3 2 # Function Description: After receiving an alarm call, you will hear the voice message prerecorded in the host, and then you can follow the prompts to perform other operations.
② Command Function: Set leaving time Command Grammar: 3 5 # D D # Function Description: “D D” refers to leaving time, also called delayed ARM time and must be a 2-digit number (00-99 minutes). Within the leaving period of time, the alarm host gives out a short “Beep” sound every 1 second, and you must leave defense zones during the time period.
⑤ Command Function: Set dialling times Command Grammar: 3 8 # D D # Function Description: “D D” refers to dialing times (01-99), namely how many times the host dials phone numbers according to a list of preset phone numbers. Note: This set-up does not apply when the host dials phone numbers of the alarm receiving centre.
2. Modify Alarm Mode and Arm/Disarm in SET Mode Enter # # # A A A A A A # to enter into set-up mode and modify alarm mode. ① Arm the host in phone alarm mode Enter 1 # to arm in phone alarm mode and exit set-up mode. ② Arm in on-site alarm mode Enter 3 # to arm in on-site alarm mode and exit set-up mode. “A A A A A A ” refers to a 6-digit set-up password. The factory default set-up password is “112233”. Once arm is completed, the host will automatically exit set-up mode and is under leaving state.
arm/disarm methods in "Arm/Disarm Operation" to arm the alarm host and to ensure the system is on alert. The alarm host will automatically alarm according to the pre-set alarm procedure as soon as someone breaks into a defense area.
phone numbers. 4. Remote Set-up Call the phone numbers pre-set for the user alarm host through fixed phone or mobile phone in other areas, and then the user alarm host will automatically pick up the phone after receiving several rings (program default: 9 times ) and at the same time you can hear a voice prompt “Welcome to Use Hengbo Security Product”. And then you can enter # # # through the keyboard of fixed phone or mobile phone, and then you can hear a voice prompt “Please enter user password”.
Operating Conditions: -10-55℃ Relative Humidity: 40-70% Dial Mode: Double Audio Frequency High Frequency Group Level: -7±2dBm Low Frequency Group Level: -9±2dBm Pick-up Resistance: ≤300Ω External Backup Battery: DC12V7Ah Dimension: 265×260×80(mm) 2. Wireless Remote Controller Operating Voltage: 12V 27mA Standby Current: ≤ 5uA Alarm Current: ≤13.5mA Transmitting Power: ≥10 mW Dimension: 35×61×14(mm) X.
XII. Failure Troubleshooting Failure Symptom Reason Power plug is not “RUN” Indicator does not properly connected, or light up when powered on socket has no power Failure Recovery Method Check power plug or socket Enter correct user password or User password is wrong, The host fails to enter into contact local distributor for or is modified or set-up mode recovering password. forgotten.
LED “Power Failure” indicator lights up and displays defense zone number. The remote distance of remote control becomes shorter. User password is wrong. When the ringing times reaches the pre-set value under long-distance operation mode, dialling sound can be heard from the phone. The battery of the detector for this defense Replace the battery zone is damaged. The voltage of the battery Replace the battery is low. User password is modified or forgotten.
11## Delete the second group of informed phone numbers Delete the third group of informed phone numbers Delete the fourth group of informed phone numbers Delete all phone numbers Select small alarm volume Select medium alarm volume Select large alarm volume Select maximum alarm volume Select mute alarm Record Playback Select playing the record Select playing the siren Set siren duration(DD=01-99 seconds) Set leaving time(DD=01-99 seconds) Set entry time(DD=01-99 seconds) Set ringing times in other areas (D
Warning: Limits of This Security System As an advanced hi-tech anti-theft system, although this product can reduce and prevent the occurrence of theft, robbery and fire and thus reduce loss, we can not guarantee no above-mentioned accidents happen or no personal casualty and property loss happens. And we invite you to understand that any alarm system, whether it is used for business or home use, may wrongly alarm or fail to alarm because of different reasons.
the alarm center, or other lines are busy, so that alarm information can not be transmitted in time. 8. The alarm system does not alarm when someone intrudes or there is an emergency alarm. The most common reason is that the alarm system does not get properly maintained. Like other electrical equipments, this equipment may be subject to electronic component damage. Therefore, users shall routinely check and maintain the system. 9. Other Unpredicted Reasons.