Model: STI-34401
Operation:
Magnetic Sensor:
Alert Signal – Magnet is over 1-1/2” from the ““ shape. (typically)
Restore Signal – Magnet is brought within 1-1/4” from the ““ shape. (typically)
Tilt Sensor:
Alert Signal – Sensor is tilted more than 45° from vertical.
Restore Signal – Sensor is tilted less than 45° from vertical.
Ext. Sensor Input:
Alert Signal – Terminals must first have a short circuit then an open circuit any
time afterward will trigger an Alert signal.
Restore Signal – Terminals have a short circuit.
NOTE: An Alert or Restore signal must be triggered for an STI receiver to
acknowledge any one of the 3 Sensor Configurations.
Sensor Trouble Detection:
If the STI Universal Sensor has a Low Battery or triggered Tamper Switch, the
sensor will send a trouble signal to the receiver. If there is a Loss of
Communication with the receiver, the receiver also will indicate a trouble
condition with that device.