User's Manual

-2- -3-
Programming Instructions:
1. Remove cover by releasing snap closure located at the bottom center.
2. Put receiver in program mode (refer to receiver instructions for programming).
3. Remove Mylar tab from battery. Unit should immediately program into receiver, if not
press the tamper switch.
4. Motion sensitivity:
· Normal sensitivity: jumper on BOTH PINS
· High sensitivity: remove jumper
Mounting Instructions:
1. Release holding tab and remove PCB (see internal view for tab location).
2. Remove screw knockouts for mounting.
3. Replace PCB. Make sure bug / insulation foam is installed.
4. Mount at 7.5ft (ideal height) with provided screws and optional anchors.
5. Replace cover. Unit immediately goes into 3 minute walk test. To reset walk test, remove
cover and reattach.
Walk Test LED:
1. LED lights for 3 minutes when motion sensed (only during walk test).
2. Wireless transmissions are sent for each detection; so walk test can be used for receiver
test as well.
3. Motion stops (locks out) sensing for 20 seconds after LED flashes.
4. When complete, replace cover fixing screw.
Operation:
1. Motion stops (locks out) transmitting wireless sensor alarms for 3 minutes after
sending an alarm transmission. This is to conserve battery life.
2. Walk Test LED does not activate in normal operating mode, only works during walk test.
3. Tamper: when cover is opened.
4. Supervisory: every hour.
Specifications:
· Mounting Hardware: #6 screw
· Mounting Height: 7.5ft (ideal height)
· Replacement battery: CR123A 1500mAH
· Temperature range: 0°F to 120°F
· Housing dimensions: 3.7” X 2.37” X 1.65”
Specifications subject to change without notice.
Side View
7.5 ft.
0
10 ft
20 ft
30 ft 40 ft
LOCK DOWN SHORT RANGE MIDDLE RANGE LONG RANGE
0
44 ft
44 ft
44 ft
Top View
BUG FOAM
BATTERY
+
PCB HOLDING TAB
WALK TEST LED
TAMPER AND WALK TEST SWITCH
MOTION SENSOR
SENSITIVITY JUMPER
MYLAR TAB