Specifications

PARAMETER 2
2-107
Classification
USER
Display title
EIA/ISO
Address Meaning Description
Fixed value (0)
Program type
Conditions
Unit
F5
Setting range
Minimum allowable height of stepped
sections for deceleration in high-speed
smoothing control mode
Program type E
Conditions After stop of movement
Unit 0.0001 mm/0.00001 inch
F6
Setting range 0 to 100
Specify the minimum height of stepped sections at which the axis feed is
not to be decelerated in high-speed smoothing control mode.
Fixed value (0)
Program type
Conditions
Unit
F7
Setting range
Corner deceleration speed coefficient for
high-speed smoothing control
Program type E
Conditions Immediate
Unit %
F8
Setting range 0 to 2000
Corner deceleration speed Vo determined by the optimal corner
deceleration function is adjusted using the value set in this parameter.
Vo = Vo ×
F8
100
The speed is not adjusted if 0 is set here. (Setting is handled as 100.)
Setting more than 2000 is disposed as 2000.