Specifications

PARAMETER 2
2-111
Classification
USER
Display title
EIA/ISO
Address Meaning Description
Maximum inside-corner angle available with
automatic corner override (G62)
Program type E
Conditions Next command
F21
Unit
Setting range 0 to 179
The automatic corner override using the G62 code becomes valid when
the following condition of the shape angle is met:
Shape angle
F21
MPL062
Overriding occurs here.
Pattern angle
Deceleration area of automatic corner
overriding (G62)
Program type E
Conditions Next command
F22
Unit
0.001 mm/0.0001 inch
(0.001°)
Setting range 0 to 99999999
The area in which automatic corner overriding using the G62 code occurs
Overriding occurs here.
F22
MPL063
Program type
Conditions
F23
to
F26
Unit
Setting range
Invalid
Handling of G92 (spindle speed clamp
value) command at restart
Program type E
Conditions Immediate
F27
Unit
Setting range 0 to 9
0: Only the last G92SsQqRr command is enabled.
1: All the G92SsQqRr commands are enabled.
2 to 8: Not used.
9: The spindel speed clamp value is invalid at restart.