Specifications
PARAMETER 2
2-111
Classification
USER
Display title
EIA/ISO
Address Meaning Description
Maximum inside-corner angle available with
automatic corner override (G62)
Program type E
Conditions Next command
F21
Unit 1°
Setting range 0 to 179
The automatic corner override using the G62 code becomes valid when
the following condition of the shape angle is met:
Shape angle
≤ F21
MPL062
Overriding occurs here.
Pattern angle
Deceleration area of automatic corner
overriding (G62)
Program type E
Conditions Next command
F22
Unit
0.001 mm/0.0001 inch
(0.001°)
Setting range 0 to 99999999
The area in which automatic corner overriding using the G62 code occurs
Overriding occurs here.
F22
MPL063
—
Program type —
Conditions —
F23
to
F26
Unit —
Setting range —
Invalid
Handling of G92 (spindle speed clamp
value) command at restart
Program type E
Conditions Immediate
F27
Unit —
Setting range 0 to 9
0: Only the last G92SsQqRr command is enabled.
1: All the G92SsQqRr commands are enabled.
2 to 8: Not used.
9: The spindel speed clamp value is invalid at restart.