Specifications

PARAMETER 2
2-113
Classification
USER
Display title
EIA/ISO
Address Meaning Description
Operating method selection in tape mode
Program type E
Conditions Immediate
F40
Unit
Setting range 0 to 3
0: Tape operation
1: Hard disc operation
2: IC memory card operation
3: Ethernet operation
Threading termination waiting time
processing
Program type M
Conditions Immediate
F41
Unit 3.5 ms
Setting range 0 to 255
Set a threading termination waiting time.
F41 = 0, 1 or 128 to 255
No waiting time
F41 = 2 to 127
(Setting – 1) × 3.5 msec
Deceleration area r during Z-axis
measurement
Program type E
Conditions After stop of movement
F42
Unit 0.001 mm/0.0001 inch
Distance (r) between the starting point of movement at measuring speed
and the measuring point
This data is used when argument R is omitted in G37 command format.
G37 Z_ Rr D_ F_;
Setting range 0 to 99999999
(G37)
Measurement area d during Z-axis
measurement
Program type E
Conditions After stop of movement
F43
Unit 0.001 mm/0.0001 inch
Range (d) where the tool should stop
This data is used when argument D is omitted in G37 command format.
G37 Z_ R_ Dd F_;
Setting range 0 to 99999999
(G37)
Return to Library