Specifications
2 PARAMETER
2-114
Classification
USER
Display title
EIA/ISO
Address Meaning Description
Measuring speed f
Program type E
Conditions After stop of movement
F44
Unit 1 mm/min / 1 inch/min
Setting range 0 to 120000
Measuring speed (f)
This data is used when argument F is omitted in G37 command format.
G37 Z_ R_ D_ Ff;
Standard setting 1 to 60000 mm/min
1 to 2362 inch/min
(G37)
Deceleration area r during X-axis
measurement
Program type E
Conditions After stop of movement
F45
Unit 0.001 mm/0.0001 inch
Setting range 0 to 99999999
Distance (r) between the starting point of movement at measuring speed
and the measuring point
This data is used when argument R is omitted in G37 command format.
G37 X_ Rr D_ F_;
(G37)
Deceleration area d during X-axis
measurement
Program type E
Conditions After stop of movement
F46
Unit 0.001 mm/0.0001 inch
Setting range 0 to 99999999
Range (d) where the tool should stop
This data is used when argument D is omitted in G37 command format.
G37 X_ R_ Dd F_;
(G37)
Common variable name
Program type —
Conditions —
F47
to
F66
Unit —
Setting range —
The name of the variable specified by the user macro SETVN is displayed
(Name display only. No setting is possible on the
PARAMETER display.)
F47: Name of #500
M M
F66: Name of #519
Return to Library