Specifications

2 PARAMETER
2-114
Classification
USER
Display title
EIA/ISO
Address Meaning Description
Measuring speed f
Program type E
Conditions After stop of movement
F44
Unit 1 mm/min / 1 inch/min
Setting range 0 to 120000
Measuring speed (f)
This data is used when argument F is omitted in G37 command format.
G37 Z_ R_ D_ Ff;
Standard setting 1 to 60000 mm/min
1 to 2362 inch/min
(G37)
Deceleration area r during X-axis
measurement
Program type E
Conditions After stop of movement
F45
Unit 0.001 mm/0.0001 inch
Setting range 0 to 99999999
Distance (r) between the starting point of movement at measuring speed
and the measuring point
This data is used when argument R is omitted in G37 command format.
G37 X_ Rr D_ F_;
(G37)
Deceleration area d during X-axis
measurement
Program type E
Conditions After stop of movement
F46
Unit 0.001 mm/0.0001 inch
Setting range 0 to 99999999
Range (d) where the tool should stop
This data is used when argument D is omitted in G37 command format.
G37 X_ R_ Dd F_;
(G37)
Common variable name
Program type
Conditions
F47
to
F66
Unit
Setting range
The name of the variable specified by the user macro SETVN is displayed
(Name display only. No setting is possible on the
PARAMETER display.)
F47: Name of #500
M M
F66: Name of #519
Return to Library