Specifications
PARAMETER 2
2-139
Classification
USER
Display title
EIA/ISO
Address Meaning Description
—
Program type M, E
Conditions At power on
F114
(bit 2)
Unit —
Setting range 0, 1
Tool shape check during tool measurement
F114 (bit 2) = 0:
During measurement for IN and EDGE tools, alarm 653 ILLEGAL TOOL
DESIGNATED occurs since the measurements are possible only at 0
degrees of the B-axis.
F114 (bit 2) = 1:
The shape of the tool is not checked.
—
Program type E
Conditions At power on
F114
(bit 3)
Unit —
Setting range 0, 1
Moving axes by using G49 (tool length cancel) in G43 (tool length offset)
mode
F114 (bit 3) = 0:
Valid
F114 (bit 3) = 1:
Invalid
—
Program type M, E
Conditions Immediate
F114
(bit 4)
Unit —
Setting range 0, 1
Selecting a rethreading function
F114 (bit 4) = 0:
Using the rethreading function
F114 (bit 4) = 1:
Not using the rethreading function
—
Program type M, E
Conditions Immediate
F114
(bit 5)
Unit —
Setting range 0, 1
Output timing of a tool life alarm
F114 (bit 5) = 0:
At the time of the next tool change
F114 (bit 5) = 1:
When the program ends.
Return to Library