Specifications
PARAMETER 2
2-155
Classification
USER
Display title
SOFT LIMIT
Address
Meaning
Description
Clamping value for the amount of handle
interruption
Program type M, E
Conditions Immediate
I12
Unit
0.001 mm
0.0001 inch
0.0001 deg
Setting range 0 to 99999999
Set the clamping value for the amount of handle interruption.
—
Program type M, E
Conditions At power on
I13
Unit Bit
Setting range Binary, eight digits
Execution of G28 (reference-point return):
0: Memory-type zero-point return
1: Watchdog-type zero-point return
Manual zero-point return operation:
0: Memory-type zero-point return
(After power-on, however, watchdog-type
zero-point return)
1: Watchdog-type zero-point return
Removal of control axes
0: No (Not removed)
1: Yes (Removed)
—
Program type M, E
Conditions After stop of movement
I14
Unit Bit
Setting range Binary, eight digits
Mirror image with respect to the machine zero-
point
0: Invalid
1: Valid
User software limits (I2, I3)
0: Valid
1: Invalid
Tool-tip relief after spindle orientation during
execution of G75, G76, G86 or point-machining
(boring or back-boring)
0: Required
1: Not required
Direction of the relief mentioned above
0: Plus
1: Minus
7 6 5 4 3 2 1 0
7 6 5 4 3 2 1 0