Specifications
PARAMETER 2
2-163
Classification
USER
Display title
SYSTEM
Address Meaning
Description
Tool turning clearance (radial value) in X-
axis
Program type M
Conditions Immediate
SU50
Unit 0.001 mm/0.0001 inch
Setting range 0 to 65535
Tool turning clearance in Z-axis
Program type M
Conditions Immediate
SU51
Unit 0.001 mm/0.0001 inch
Setting range 0 to 65535
Tool turning clearance is required to prevent interference between the tool
and stock material during tool change in automatic operation.
SU51
Chuck
Dmax: Stock material maximum outside diameter
l
0
: Stock material edge projection length
Stock material shape
l
0
Dmax
SU50
NM211-00220
Lower-turret retraction function
Tool number of the retraction tool
Program type M
Conditions Immediate
SU52
SU53
Unit —
Setting range 0 to 960
Set the tool to be retracted to the fixed position for the automatic lower-
turret retraction function. Specify the tool number of the lower turret.
SU52: Tool number of Retraction tool 1
SU53: Tool number of Retraction tool 2
—
Program type —
Conditions —
SU54
to
SU96
Unit —
Setting range —