Specifications
2 PARAMETER
2-164
Classification
USER
Display title
SYSTEM
Address Meaning
Description
Lower-turret retraction function
Fixed point of the retraction position
Program type M
Conditions Immediate
SU97
to
SU100
Unit 0.001 mm/0.0001 inch
Setting range 0 to 99999999
Set the position where the turret is to be retracted for the turret retraction
function. Specify coordinates in the machine coordinate system based on
the machine zero point.
Machine zero point
Fixed point 1
Fixed point 2
SU100
SU98
SU97
SU99
SU97: X-axis retraction point – Fixed point 1
SU98: Z-axis retraction point – Fixed point 1
SU99: X-axis retraction point – Fixed point 2
SU100: Z-axis retraction point – Fixed point 2
Specify a minus value if the fixed point of the retraction position is located
in a minus direction when viewed from the zero point of the machine
coordinates.
Note:
Set this parameter for the system of the lower turret.
Return distance (radial value) in X-axis at
wall during rough cutting in bar machining
or in corner machining of EIA/ISO program
Program type M, E
Conditions Immediate
SU101
Unit 0.0001 mm/0.00001 inch
Setting range 0 to 65535
Return distance (radial value) in Z-axis at
wall during rough cutting in bar machining
or in corner machining of EIA/ISO program
Program type M, E
Conditions Immediate
SU102
Unit 0.0001 mm/0.00001 inch
Setting range 0 to 65535
Example 1:
Standard type cutting
Prior to cutting up along the wall in the end of final cycle, escape will be
made by specified distance.
SU102
SU101
Example 2:
High speed rough cutting
Escape will be made by SU101 and SU102 specified distance during
return after reaching the wall.
SU101
SU102
Return to Library