Specifications
2 PARAMETER
2-198
Classification
USER
Display title
TURNING
Address Meaning
Description
CUTTING CONDITON LEARN display
— Max. workpiece outside diameter range
Program type M
Conditions Immediate
TC114
to
TC116
Unit 1 mm/0.1 inch
Setting range 0 to 65535
Specify the maximum outside diameter range of the workpieces displayed
on the
CUTTING CONDITON LEARN display.
Specify the range so that the relational expression of
TC114 < TC115 < TC116 is established.
Composite-type fixed cycle
— G273/G73 amount of X-axial release
Program type E
Conditions Immediate
TC117
Unit 0.001 mm/0.0001 inch
Setting range 0 to 65535
Composite-type fixed cycle
— G273/G73 amount of Z-axial release
Program type E
Conditions Immediate
TC118
Unit 0.001 mm/0.0001 inch
Setting range 0 to 65535
The settings of these parameters will be used if the amount of release is
not specified in the program.
TC117
TC118
—
Program type —
Conditions —
TC119
Unit —
Setting range —
Invalid