Specifications
PARAMETER 2
2-201
Classification
USER
Display title
TURNING
Address Meaning
Description
Selection between use/disuse of
acceleration distance check at start of
thread cutting unit
Program type M
Conditions Immediate
TC141
(bit 2)
Unit —
Setting range 0, 1
TC141 (bit 2) = 0: Disuse
Alarm not caused even if acceleration distance at start of thread cutting
unit exceeds clamp data
TC141 (bit 2) = 1: Use
Alarm caused when acceleration distance at start of thread cutting unit
exceeds clamp data
Example:
L
o
L
o
L
c
L
o
: Acceleration distance
L
c
: Acceleration distance clamp data
Start of
thread
cutting
→
Alarm not caused
→
Alarm caused
(!TC77)
Selection between start position shift/start
angle shift for thread number offset in
thread cutting unit
Program type M
Conditions Immediate
TC141
(bit 3)
Unit —
Setting range 0, 1
TC141 (bit 3) = 0: Start position shift
Thread number offset adjusted by moving thread cutting start position
1st thread
2nd thread
3rd thread
A
cceleration distance
changes according to the
thread number
TC141 (bit 3) = 1: Start angle shift
Thread number offset adjusted according to thread cutting start angle
1st thread
2nd thread
3rd thread
A
cceleration distance is
same for any thread
number