Specifications

2 PARAMETER
2-214
Classification
MACHINE
Display title
MEASURE
Address Meaning Description
Specification of measuring tolerance
(lower limit)
Program type M, E
Conditions Immediate
K17
Unit %
Setting range 0 to 100
Specification of measuring tolerance
(upper limit)
Program type M, E
Conditions Immediate
K18
Unit %
Setting range 0 to 100
(1) Tool compensation will be made in cases below.
a
1
– a
2
100
×
K18
Compensation data
a
1
– a
2
100
×
K17
a
1
– a
2
100
×
K17
Compensation data
a
1
– a
2
100
×
K18
(2) Tool compensation will not be made in cases below.
a
1
– a
2
100
×
K17
> Compensation data > –
a
1
– a
2
100
×
K17
(3) Alarm will be caused in cases below.
Compensation data >
a
1
– a
2
100
×
K18
a
1
– a
2
100
×
K18
> Compensation data
where a
1
= Tolerance upper limit
a
2
= Tolerance lower limit (Specified in program)
Note:
1. Up to 100 % can be set.
2. Offset judgement occurs only when L106 bit 6 ist set to 1.
Measurement stroke for workpiece
measurement
Program type M
Conditions Immediate
K19
Unit 0.001 mm/0.0001 inch
Setting range 0 to 65535
Measurement re
g
ion
d
c
b
a
NM211-00259
K19
a : Approach point
b : Measurement start point
c : Measurement point
(target data)
d : Measurement end point
K19
Measurement stroke for tool nose
measurement
Program type M
Conditions Immediate
K20
Unit 0.001 mm/0.0001 inch
Setting range ±99999999
K20K20
K20
K20
TOOL EYE
reference
point #1
TOOL EYE
reference
point #2
TOOL EYE
reference
point #3
TOOL EYE
reference
point #4