Specifications

2 PARAMETER
2-228
Classification
MACHINE
Display title
MEASURE
Address Meaning Description
Special linear acceleration/deceleration
time constant for threading
Program type M, E
Conditions After stop of movement
K85
Unit msec
Setting range 0 to 300
If the setting of K85 is from 1 to 3 msec, this setting will be used as the
linear acceleration/deceleration time constant for the G32 threading block.
If the setting is outside the valid range, however, the normal linear
acceleration/deceleration time constant for G01 will be used.
Program type
Conditions
K86
to
K89
Unit
Setting range
Invalid
Return override during synchronous
tapping
Program type E
Conditions After stop of movement
K90
Unit 1%
Setting range 0 to 999
The overriding value for return from the hole bottom during a synchronous
tapping cycle
Programmed
feed rate
×
K90
100
MPL509
Note:
This parameter is valid only when bit 6 of F94 is 1.
Alternative M-code for M96
Program type M, E
Conditions Immediate
K91
Unit
Setting range 0 to 127
Specify an alternative M-code for M96 when user macro interruption is
valid.
Return to Library