Specifications
2 PARAMETER
2-240
2-3-11 Machine parameter TABLE (L)
Classification
MACHINE
Display title
TABLE
Address Meaning Description
Stylus eccentricity of touch sensor
(X-component)
Program type M
Conditions At power on
L1
Unit 0.0001 mm/0.00001 inch
Setting range 0 to ±99999999
Stylus eccentricity of touch sensor
(Y-component)
Program type M
Conditions At power on
L2
Unit 0.0001 mm/0.00001 inch
Setting range 0 to ±99999999
The eccentricity of the stylus of the touch sensor with respect to the center
of the spindle
MPL09
3
L1
L2
+Z
+
X
+Y
+
X
St
y
lus
Spindle centerline
Stylus
centerline
Touch sensor
Note:
These data are automatically set when calibration measurement is
performed using the MMS unit.
Radius of stylus ball of touch sensor
(X-component)
Program type M
Conditions At power on
L3
Unit 0.0001 mm/0.00001 inch
Setting range 0 to ±99999999
Radius of stylus ball of touch sensor
(Y-component)
Program type M
Conditions At power on
L4
Unit 0.0001 mm/0.00001 inch
Setting range 0 to ±99999999
The true radius value of the stylus ball of the touch sensor
MPL09
4
Touch sensor
Stylus ball
+Z
+
X
+Y
+
X
L3
× 2
L4
× 2
Note:
These data are automatically set when calibration measurement is
performed using the MMS unit.
Return to Library