Specifications
PARAMETER 2
2-243
Classification
MACHINE
Display title
TABLE
Address Meaning Description
Tolerance for manual measurement
Program type M, E
Conditions Immediate
L12
Unit 0.0001 mm/0.00001 inch
Setting range 0 to ±99999999
Tolerance for Z coordinate value in circle measurement
L12
Tolerance for measured coordinate value in face measurement
L12
Y
X
MPL512
Allowable angle for parallelism and right
angle in manual measurement
Program type M
Conditions Immediate
L13
Unit 0.0001°
Setting range 0 to ±900000
Set the allowable angle for calculation of parallelism and right angle to be
measured manually.
Note:
When error angle is smaller than the setting angle, the parallelism and
right angle are calculated.
Escapement for straightness measurement
Program type M
Conditions Immediate
L14
Unit 0.0001 mm/0.00001 inch
Setting range 0 to ±99999999
Set an escape amount from a measurement point to the next point in
straightness measurement.
L14
MPL513