Specifications

2 PARAMETER
2-244
Classification
MACHINE
Display title
TABLE
Address Meaning Description
Macro program number for straightness
measurement
Program type M
Conditions Immediate
L15
Unit
Setting range 0 to 99999999
Set macro program number for straightness measurement.
Before shipment, the macro program is numbered “9999” at the factory.
Fixed value
Program type
Conditions
L16
Unit
Setting range
Parameter for system internal setting
Setting prohibited
Program type
Conditions
L17
Unit
Setting range
Invalid
Presence/absence of tailstock
Program type M, E
Conditions Immediate
L18
Unit
Setting range 0, 1
0: Tailstock absent.
1: Tailstock present.