Specifications

2 PARAMETER
2-246
Classification
MACHINE
Display title
TABLE
Address Meaning Description
Data of the tool nose measurement sensor
L22 : Sensor width along the X-axis
L23 : Sensor width along the Z-axis
L24 : X-coordinate of the sensor’s
reference point
L25 : Z-coordinate of the sensor’s
reference point
Program type M
Conditions Immediate
L22
to
L25
Unit 0.0001 mm/0.00001 inch
Setting range ±99999999
Use L22 and L23 to set the dimensions of the sensor for tool nose
measurement.
L24 and L25 are provided to set in machine coordinates the reference
point of the sensor (see the diagram below).
[INTE IV, INTE e-HII, lathes]
Example 1: For No. 1 turning spindle
L23
L22
L25
L24
Sensor’s
reference point
Sensor for tool nose
measurement
Machine zero point
Set the imaginary upper left corner of the sensor as its reference point for
No. 2 spindle.
[INTE e-VII]
Example 2:
L22
L23
L24
L25
Sensor’s
reference point
Sensor for tool nose
measurement
Machine zero point
Note:
As shown above, the X- and Z-axes must be replaced with each other
between INTEGREX e-HII and e-VII.
Tool nose measurement sensor reference
position, Y-axis
Program type M
Conditions Immediate
L26
Unit 0.0001 mm/0.00001 inch
Setting range ±99999999
Setting of sensor reference point Y coordinate
Machine zero point
L26