Specifications
PARAMETER 2
2-261
Classification
MACHINE
Display title
TABLE
Address Meaning Description
Correction value of alignment deviation X
(0-degree face)
Program type M
Conditions After stop of movement
L86
Unit 0.0001 mm/0.00001 inch
Setting range 0 to ±99999999
Correction value of alignment deviation Y
(0-degree face)
Program type M
Conditions After stop of movement
L87
Unit 0.0001 mm/0.00001 inch
Setting range 0 to ±99999999
2
#
My
2
#
Mx
ex
ey
Spindle center
Stylus
MPL519
ex: Alignment deviation correction value on X-axis
ey: Alignment deviation correction value on Y-axis
Mx: Stylus radius in the X-axis direction (The setting of L3)
My: Stylus radius in the Y-axis direction (The setting of L4)
Note:
The data is set automatically by execution of calibration measurement (0-
degree face) with the MMS unit.
(For five-surface machining)
Correction value of alignment deviation X
(90-degree face)
Program type M
Conditions After stop of movement
L88
Unit 0.0001 mm/0.00001 inch
Setting range 0 to ±99999999
Correction value of alignment deviation Y
(90-degree face)
Program type M
Conditions After stop of movement
L89
Unit 0.0001 mm/0.00001 inch
Setting range 0 to ±99999999
2
#
My
2
#
Mx
ex
ey
Spindle center
Stylus
MPL519
ex: Alignment deviation correction value on X-axis
ey: Alignment deviation correction value on Y-axis
Mx: Stylus radius in the X-axis direction (The setting of L3)
My: Stylus radius in the Y-axis direction (The setting of L4)
Note:
The data is set automatically by execution of calibration measurement
(90-degree face) with the MMS unit.
(For INTEGREX series)
(For five-surface machining)
Return to Library