Specifications
PARAMETER 2
2-263
Classification
MACHINE
Display title
TABLE
Address Meaning Description
X/Y travel distance during EIA-programmed
tool measurement
Program type E
Conditions Immediate
L94
Unit —
Setting range 0, 1
The X/Y travel distance can be set during the selection of EIA-
programmed fully automatic tool length measurement on the TOOL
OFFSET display.
0: Invalid
1: Valid
Note:
Valid only when the measuring equipment to be used for the tool
measurement is a measuring table (L106 bit 0 = 0).
Offset number auto-setting for EIA-
programmed tool measurement
Program type E
Conditions Immediate
L95
Unit —
Setting range 0, 1
The offset number is auto-set during EIA-programmed tool measurement
data setting.
0: Invalid
1: Valid
Note:
When making the auto-setting function valid, see the description of L96.
Offset for EIA-programmed tool
measurement
Program type E
Conditions Immediate
L96
Unit —
Setting range 0 to 4000
The amount of shifting for TNo. during offset number auto-setting for EIA-
programmed tool measurement data setting.
[Offset No.] = [TNo. setting] + [L96 setting]
Note:
Valid only when L95 = 1.
—
Program type —
Conditions —
L97
Unit —
Setting range —
Invalid