Specifications

PARAMETER 2
2-277
Classification
MACHINE
Display title
FEED VEL.
Address Meaning Description
Maximum software limit specified by
manufacturer (+ direction)
Program type M, E
Conditions After stop of movement
M8
Unit
0.0001 mm/0.0001 deg
Setting range ±99999999
Maximum software limit specified by
manufacturer (– direction)
Program type M, E
Conditions After stop of movement
M9
Unit
0.0001 mm/0.0001 deg
Setting range ±99999999
The maximum moving zone permissible under the machine specifications
Set the machine coordinate values.
Example:
+Y
+X
Moving zone
M8
(X-axis)
M9
(X-axis)
M9
(Y-axis)
M8
(Y-axis)
MPL522
Note:
This parameter is invalid when M8 = M9.
Command unit
Program type E
Conditions At power on
M10
Unit
Setting range 1 to 50000
Select a unit of command from the following table and set it.
* micron system
Coding of address of axis
Program type M, E
Conditions At power on
M11
Unit
Setting range &0 to &7F
Register the address of each axis in hexadecimal numbers in ASCII code.
1000* 100* 10* 1* 0.1*
10000 1000 100 10 1
2° index 20000 2000 200 20 2
5° index 50000 5000 500 50 5
X-axis Y-axis Z-axis 4th-axis 5th-axis 6th-axis
Address name X Y Z A B C
Set value &58 &59 &5A &41 &42 &43
Fixed value
Return to Library