Specifications

2 PARAMETER
2-278
Classification
MACHINE
Display title
FEED VEL.
Address Meaning Description
Coding of incremental axis
Program type M, E
Conditions At power on
M12
Unit
Setting range &0 to &7F
Register the incremental axes respectively in hexadecimal numbers of the
ASCII code.
Axis name (for display)
Program type M, E
Conditions Immediate
M13
Unit
Setting range &0 to &7F
Specify the address name of the axes to be used for display, by the
appropriate hexadecimal number of the ASCII code.
For reverse display, set up the most significant bit.
Example 1: Reverse display of “C”
C : &0043 Reverse display of “C”: &00C3
Example 2: Reverse display of “X1”
X1 : &5831 Reverse display of “X1”: &D831
Shifting distance of the watchdog-less home
position
Program type M, E
Conditions Immediate
M14
Unit
0.0001 mm/0.0001 deg
Setting range ±99999999
When the watchdog-less home position is set, it will be shifted through the
distance
<If returning to the zero point is not yet executed>
M14
Signal ON
position
Zero point
<If returning to the zero point is executed>
Ex-
M14
New
M14
Ex-zero
point
M14
changing
position
Zero
point
Return to Library