Specifications
2 PARAMETER
2-280
Classification
MACHINE
Display title
FEED VEL.
Address Meaning Description
Axis control flag
Program type M, E
Conditions At power on
M18
Unit Bit
Setting range Binary, eight digits
Type of C-axis
0: Motor type with frame
1: Built-in type
Machine zero-point position
0: Fixed point for zero-point return using
watchdogs
1: Position existing when power was turned on
Watchdog-less axis
X-axis current position display
0: Radius
1: Diameter
Automatic/manual simultaneous absolute-value
updating
0: Invalid
1: Valid
Absolute-value detection
0: Invalid
1: Valid
Axis control flag
Program type M, E
Conditions At power on
M19
Unit Bit
Setting range Binary, eight digits
Select an in-position checking method
0: NC
1: Servo
Homing operation starting position check
0: No check
1: Alarm if returned from the top of the watchdog
Backlash scheme to be adopted for watchdog-type
returning to home position
0: G01
1: G0
Axis control flag
Program type M, E
Conditions At power on
M20
Unit Bit
Setting range Binary, eight digits
Rotational direction of the rotation axis
0: Forward
1: Reverse
M18 bit 7
01
0
Dog type
Simplified detection
position
SV17
bit 7
1
Dog type
Absolute detection
position
7 6 5 4 3 2 1 0
7 6 5 4 3 2 1 0
7 6 5 4 3 2 1 0
Return to Library