Specifications

2 PARAMETER
2-302
2-3-15 Machine parameter SPINDLE (SA)
Classification
MACHINE
Display title
SPINDLE
Address Meaning Description
Maximum RPM of spindle in each speed
range (range 1 to 8)
Program type M, E
Conditions At power on
SA1
to
SA8
Unit 1 min
–1
(rpm)
Setting range 0 to 99999
Number of revolutions per minute of the spindle in each speed range
Example:
Output voltage
SA9
SA1
SA10
SA2
min
–1
(rpm)
(Spindle speed)
MAX
L
H
Constants for calculating each gear speed
of the spindle (range 1 to 8)
Program type M, E
Conditions At power on
SA9
to
SA16
Unit 1 min
–1
(rpm)
Setting range 0 to 99999
Constants for calculating each gear speed of the spindle
(! SA1, SA2, SA3, SA4)
Maximum number of speed ranges
Address
1234
SA1
"
LLL
SA2 Invalid H M ML
SA3 Invalid Invalid H MH
SA4 Invalid Invalid Invalid H
Maximum number of speed ranges
Address
1234
SA9 " LLL
SA10 Invalid H M ML
SA11 Invalid Invalid H MH
SA12 Invalid Invalid Invalid H