Specifications
ALARM 3
3-47
No. Message
Type of
error
Stopped
status
Clearing
procedure
Display
563 PRINTER I/O ERROR (Cause, , ) G L S Blue
Cause
An error in printer communications has occurred during measurement result printing.
Action
- Check the printer for correct connection.
- Check for differences in the RS-232C parameter settings between the printer and NC unit.
564 —— ( , , )
Cause
——
Action
——
565 ID MIS-CONNECTED ( , , ) G L S Blue
Cause
Erroneous cable connection has occurred during connection of the ID unit and the NC unit, or power has remained turned
off.
Action
Check for incorrect cable connections.
Or check if the power is turned on.
566 POWER STOPPED DURING ID OPER. ( , , ) A L S Blue
Cause
Power has been turned off during the operation of the ID unit.
Action
Check the current tool data, and if errors are found, operate the unit once again.
567 ID I/O ERROR ( , , ) G L S Blue
Cause
Communication between the NC unit and the ID unit has become interrupted because of hardware trouble (such as line
noise).
Action
Contact Mazak Technical Center or Technology Center.
568 —— ( , , )
Cause
——
Action
——
569 —— ( , , )
Cause
——
Action
——
570 NO DNC OPTION ( , , ) A L S Blue
Cause
DNC operation was attempted although DNC option is not provided.
Action
Provide the NC unit with a DNC option. (Only with this option, DNC operation can be carried out.)
571 ILLEGAL FORMAT ( , , ) A L S Blue
Cause
Data other than MATRIX use data has been transmitted from the host system. (The format of the transmitted data is not
correct.)
Action
Check the transmitted data for appropriateness to the MATRIX.