Specifications
2 PARAMETER
2-46
7. SPINDLE (SA)
Address
(bit)
Outline
SA1 - SA8 Maximum RPM of spindle in each speed range (range 1 to 8)
SA9 - SA16 Constants for calculating each gear speed of the spindle (range 1 to 8)
SA17 - SA24 Maximum RPM of spindle during tapping cycle (range 1 to 8)
SA25 - SA32 Spindle speed during gear shifting (range 1 to 8)
SA33 - SA40 Acceleration/deceleration time constant for the synchronous tapping (range 1 to 8)
SA41 Spindle orientating speed
SA42 Minimum spindle speed
SA43 Channel number for the spindle amplifier
SA44 Spindle amplifier rotary switch number
SA45 0
Spindle speed range changing method, in relation to switching the torque factors for auto-pecking of the
cutting load detection type
1
Spindle speed range changing method, in relation to switching the torque factors for auto-pecking of the
cutting load detection type 2
2 Homing direction for synchronous tapping
3 Homing direction for synchronous tapping
4 Defines the specified direction as the Z-phase detection direction
5 Spindle index gear correction
6—
7—
SA46 0 Direction of orientation
1 Direction of orientation
2 C-axis position control changeover type
3 Synchronous tapping position control changeover type
4 Z-phase detection direction
5 C-axis homing direction
6 C-axis homing direction
7 Synchronous tapping command polarity
SA47 0 —
Return to Library