Specifications
PARAMETER 2
2-75
Classification
USER
Display title
POINT
Address Meaning Description
Auto-set feed rate for planetary tapping
cycle
Program type M
Conditions Immediate
D51
Unit
0.01 mm/rev
0.001 inch/rev
Setting range 0 to 999
The feed rate will be auto-set to
D51 when the planetary tapping cycle is
selected.
SNo. TOOL NOM-
φ
No.HOLE-
φ
HOLE-DEP PRE-DIA PRE-DEP RGH DEPTH C-SP FR M M
1 TAP M10. 10. 23.7 PLANET 0.15 FIX P1.5 50 0.04
↑
D51
Reduction ratio for the G00-based relief
rate during a very-deep-hole drilling cycle
Program type M
Conditions Immediate
D52
Unit %
Setting range 0 to 100
Set the reduction ratio for the G00-based relief rate during the very-deep-
hole drilling in a drilling or turning-drilling unit.
Rapid feed (G00)
Cutting feed
Number of times of pecking up to the return
of the tool to a position near the starting
point of the very-deep-hole drilling cycle of
a drilling or turning-drilling unit
Program type M
Conditions Immediate
D53
Unit Times
Setting range 0 to 9999
Set the number of times of pecking to be executed before returning the
tool to a position near the starting point of the very-deep-hole drilling cycle
of a drilling or turning-drilling unit.
Example: If D53 = 3:
Cutting feed
Rapid feed
Ending point
Starting
point
After pecking has been
repeated three times, the
tool returns to a position
near the starting point.