Operation Manual

Sagab by Elma
900
10
Appropriate usage
The instrument may only be used under those conditions and for those purposes for which
it was conceived. For this reason, in particular the safety references, the technical data
including environmental conditions and the usage in dry environments, must be followed.
When modifying or changing the instrument, the operational safety is no longer ensured.
The instrument may only be opened by an authorized service technician, e.g. for fuse
replacement.
Specifications
LED voltage range 12, 24, 36, 50, 120, 230, 400V AC/DC
LED resolution ±12, 24, 36, 50, 120, 230, 400V AC/DC
Tolerances -30% to 0% of reading
Voltage detection Automatic
Polarity detection Full range
Range detection Automatic
Response time <0.1s LED
ACV frequency range 50/60Hz
Internal basic load Approx. 10W at 400V
Peak current 1s<0,2A/ (5s <3,5mA)
Operation time 30s
Recovery time 10 min
LED on About 12V AC/DC
Impedance 450k
Temperature range -10°C to +55°C
Humidity Max 85% relative humidity
Overvoltage class CATIII 400V
Voltage tester description
1. Instrument test probe [+] (L1)
2. Handle test probe [-] (L2)
3. LED voltage display