Telecommunication Network Router User's Manual
SAGEM 3P@C
3P@C Installation Manual
Page 8-2 Reproduction and communication in any form prohibited without the written permission of SAGEM SA
Table 1-3 Parameter table on the modules of SFP optical interface
Type Rate
(bps)
Optical
fiber
mode
Maximum
transmissio
n distance
Optical
connect
or type
Transmitt
ing
center
waveleng
th (nm)
Transmit
ting
optical
power
(dBm)
Receivi
ng
overlo
ad
point
(dBm)
Receivi
ng
sensitivi
ty
((dBm)
SFP-SM-155M-15K 155 M Single
mode
15 LC 1,310 -15 ~ 0 -8 -28
SFP-SM-155M-40K 155 M Single
mode
40 LC 1,310 -5 ~ 0 -10 -34
SFP-SM-155M-80K 155 M Single
mode
80 LC 1,550 -5~0 -10 -34
SFP-SM-622M-15K 622 M Single
mode
15 LC 1,310 -15 ~ 0 -8 -28
SFP-SM-622M-40K 622 M Single
mode
40 LC 1310 -5~ 2 -8 -28
SFP-SM-622M-80K 622 M Single
mode
80 LC 1,550 -5 ~ 2 -8 -28
SFP-SM-1.25G-10K 1.25
G
Single
mode
10 LC 1,310 -5~0 -3 -23
SFP-SM-1.25G-30K 1.25
G
Single
mode
30 LC 1,310 -4 ~ 2 -3 -20
SFP-SM-1.25G-40K 1.25
G
Single
mode
40 LC 1,310 -5 ~ 2 -3 -21
SFP-SM-1.25G-70K 1.25
G
Single
mode
70 LC 1,550 -2~5 -3 -22
SFP-SM-1.25G-110K 1.25
G
Single
mode
110 LC 1,550 0 ~ 5 -9 -30
SFP-SM-2.5G-15K 2.5 G Single
mode
15 LC 1,310 -10 ~ 2 -9 -18
SFP-SM-2.5G-40K 2.5 G Single
mode
40 LC 1,310 -10 ~ 3 -9 -19
SFP-SM-2.5G-70K 2.5 G Single
mode
70 LC 1,550 -10 ~ 3 -9 -19
Table 1-4 Parameter table on the modules of XENPAK optical interface
Type Rate
(bps)
Optical
fiber
mode
Maximum
transmis
sion
distance
Conne
ctor
Type
Transmittin
g center
wavelength
(nm)
Transmitti
ng optical
power
Receivi
ng
overloa
d point
(dBm)
Receivi
ng
sensitivi
ty
(dBm)
Xenpak-SM-10G-10K 10 G Single
mode
10 SC 1310 -8.2~0.5 0.5 -10.3
8.2.
8.2.8.2.
8.2. Checking the Status of the User Port
8.2.1.
8.2.1.8.2.1.
8.2.1. Querying the ADSL Port Status
You can query the ADSL port information by executing the commands below:
show port [portlist|all|active]: Show the current information of the port
show port [portlist|all|active] adsl line-config: Show the configuration information of the
ADSL port
The first command is used to show the current information that is subject to update in real time. The second
command is used to show configuration information that does not vary with the port link status.